Circuit Breakers (Low Capacity)

Circuit Breakers (Low Capacity) products from the Electrical & Controls category can be selected based on many product specifications such as Rated block capacity AC 200 V, Rated block capacity AC 400 V, Number of Poles, Rated Current, Mounting Method. The recommended brands for Circuit Breakers (Low Capacity) are DACO, DONG A ELECTRIC DEVICE, JINHUENG ELEC. The products of Circuit Breakers (Low Capacity) are offered in a total of 3 items and the product details can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies. Wide range variety of product, on time free shipping and no minimum order.
CAD
Days to Ship
  • All
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

3 itemsMặt hàng

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Molded Case Circuit Breakers (MCCB) NF-SGV Series

    Molded Case Circuit Breakers (MCCB) NF-SGV Series

    MITSUBISHI

    Ampere frame Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Rated Braking Capacity at Rated Voltage of VDC 250(kA) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current(A) Mounting Method Connection Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm)
    - - 85 36 - - 2 / 3 / 4 32-40 Fasten With Screws Surface type - 165 105 ~ 140 92
    Days to Ship: Số ngày giao hàng: 30 Day(s) or more
    day to ship 30 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Molded Case Circuit Breakers (MCCB) NF-HGV Series

    Molded Case Circuit Breakers (MCCB) NF-HGV Series

    MITSUBISHI

    Ampere frame Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Rated Braking Capacity at Rated Voltage of VDC 250(kA) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current(A) Mounting Method Connection Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm)
    - - 100 75 - - 2 / 3 / 4 32-40 - Surface type - 165 105 ~ 140 92
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
  • You can add up to 6 items per a category to the compare list.

    Molded Case Circuit Breakers (MCCB) NF-LGV Series

    Molded Case Circuit Breakers (MCCB) NF-LGV Series

    MITSUBISHI

    Ampere frame Rated block capacity AC 100 V(kA) Rated block capacity AC 200 V(kA) Rated block capacity AC 400 V(kA) Rated Braking Capacity at Rated Voltage of VDC 250(kA) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current(A) Mounting Method Connection Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm)
    - - 90 50 - - 2 / 3 / 4 32-40 - Surface type - 165 105 ~ 140 92
    Days to Ship: Số ngày giao hàng: Quote
    day to ship Quote
BrandNhãn hiệu
Product SeriesDòng sản phẩm
From
Days to ShipSố ngày giao hàng
Ampere frame
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Rated Braking Capacity at Rated Voltage of VDC 250(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Number of Poles
Rated Current(A)
Mounting Method
Connection Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)

    You can add up to 6 items per a category to the compare list.

    Molded Case Circuit Breakers (MCCB) NF-SGV Series

        You can add up to 6 items per a category to the compare list.

        Molded Case Circuit Breakers (MCCB) NF-HGV Series

            You can add up to 6 items per a category to the compare list.

            Molded Case Circuit Breakers (MCCB) NF-LGV Series
              BrandNhãn hiệu

              MITSUBISHI

              MITSUBISHI

              MITSUBISHI

              Product SeriesDòng sản phẩm

              Molded Case Circuit Breakers (MCCB) NF-SGV Series

              Molded Case Circuit Breakers (MCCB) NF-HGV Series

              Molded Case Circuit Breakers (MCCB) NF-LGV Series

              From
              Days to ShipSố ngày giao hàng 30 Day(s) or more Quote Quote
              Ampere frame---
              Rated block capacity AC 100 V(kA)---
              Rated block capacity AC 200 V(kA)8510090
              Rated block capacity AC 400 V(kA)367550
              Rated Braking Capacity at Rated Voltage of VDC 250(kA)---
              Rated block capacity, voltages except VAC 100/200/400, VDC 250---
              Number of Poles2 / 3 / 42 / 3 / 42 / 3 / 4
              Rated Current(A)32-4032-4032-40
              Mounting MethodFasten With Screws--
              Connection MethodSurface typeSurface typeSurface type
              Representative Standard---
              Dimension height(mm)165165165
              Dimension width(mm)105 ~ 140105 ~ 140105 ~ 140
              Dimension depth(mm)929292

              Loading...Tải…

              1. 1

              Related Categories to Circuit Breakers (Low Capacity)Danh mục liên quan đến Circuit Breakers (Low Capacity)

              FAQ Circuit Breakers (Low Capacity)

              Question: Types of circuit breaker and their applications.
              Answer: Circuit breakers mainly are categorized based on application as per voltage.
              1. Low Voltage Circuit Breaker
              Low-voltage circuit breakers are typically used in applications such as lighting circuits, motor control centers, feeder circuits, and any application in which electrical power needs to be turned on and off and overcurrent protection is required.
              2. Medium Voltage Circuit Breakers
              Medium voltage breakers are designed to be operated electrically by a closing solenoid or a stored energy mechanism. Manual operation is used primarily for breaker maintenance.
              3. HIGH-VOLTAGE CIRCUIT BREAKERS
              High-voltage circuit breakers are mechanical switching devices that connect and break current circuits (operating currents and fault currents) and carry the nominal current in the closed position.
              Question: What can cause the main circuit breaker to trip?
              Answer: The most common cause of a tripped circuit breaker is an overload in that circuit. Each circuit is only intended to carry a certain electrical load, and if it exceeds this load, it will cause the breaker to trip. This is important, as overloading a circuit can cause the wiring to heat up and potentially create a fire risk. In fact, it is this excess heat running through the circuit that causes the breaker to trip.
              Question: How we know that have to replace breaker?
              Answer: 1. Breaker trips frequently.
              2. Burning smell coming from the electrical panel.
              3. Poorly performing appliances and light fixtures.
              4. Breaker fails to stay in reset mode.
              5. Visible signs of physical damage.
              Question: How do I know whether to get a 15 or 20 A circuit breaker?
              Answer: Calculate the total current of all electrical equipment. that want to be connected to the breaker The sum of the calculated current should not exceed 80% of the breaker capacity. For example, a 15 A breaker can be connected to external devices up to 12A (15 x 0.80 = 12), and a 20 A breaker can be connected to external devices up to 16A (20 x 0.80 = 16). This can lead to calculation errors and can cause a fire.